@wanderinghermit @ai6yr I went with crimping everything and using MC4 connectors.

Soldering is not up to code here because when high currents (up to 35A regular current per string) heat up the connection it could in theory melt the solder.

Here my fuse box for the roof system.

10A Fuses with 3 Strings for each east/west side of the roof merging into one 16mm² connection with over voltage protection: